Observed signal levels:

 none         DUT813
115.2912     115.0930
115.2888     115.0904
115.2884     115.0945
115.2899

      averages 
115.2896     115.0926

Standard deviations of individual measurements
 0.0012      0.0021

Standard deviations of averages
 0.0006     0.0012

Standard deviation on insertion loss 0.0015

IL = 115.2896 -  115.0926 = 0.1969 dB

Error limits (3 sigma) +/- 0.0044 dB

Errors are estimated from too few data points so
error estimation for this particular measurement is 
uncertain.
There are many measurements in this series so the statistics